v6.2 to v7.0¶
This release is coordinated with OpenStudio-HEScore v2.0.
What’s New¶
Envelope¶
EPS wall type will now be selected if there is any continuous insulation on the wall, not just if it has the
InsulationMaterial/Rigid
subelement. See Wood Frame Walls.Assembly R-values can be used in for floors, attics, roofs, and walls.
More R-values are now available in the HEScore construction codes for floors, attics, roofs, and walls. No action is required. Existing HPXML elements will be translated accordingly.
A blower door test no longer requires the
AirInfiltrationMeasurement/TypeOfInfiltrationMeasurement
element. If a CFM50 or ACH50 value is reported, it will be used. See Blower Door Test.Added support for knee walls. See Knee Walls.
Either an
AirInfiltrationMeasurement
orAirSealingMeasurement
element is now required.Ducts in the garage will now be translated to unvented crawlspace in HEScore. See Duct Location Mapping.
HVAC¶
Insulated ducts can now be specified by either the
DuctInsulationThickness
or theDuctInsulationMaterial
elements. See Duct Insulation.Additional duct locations are now available. See Duct Location Mapping.
Duct blaster measurements can be used to describe duct leakage. See Duct Leakage Measurements.
Water Heating¶
The maximum allowed EF for a tank type water heater is now 0.95, and the maximum allowed EF for a tankless water heater is 0.99. Electric heat pump water heaters will continue to allow EFs between 1.0 and 4.0 inclusive.
PV¶
PV Tilt is translated and used in HEScore. See Panel Tilt.
Number of Panels is now being translated from HPXML v3 files. See Number of Panels.
Changelog¶
Move external_building_id to building_address element by @bpark1327 in #149
JSON Schema by @bpark1327 in #144
Failing CI on broken tests for all versions by @nmerket in #159
Wall translation fixes and water heater EF rounding by @bpark1327 in #164
Update duct insulation mapping by @bpark1327 in #163
JSON Schema, take 2 by @bpark1327 in #161
not allowing R-value to go past zero for walls with XPS by @nmerket in #170
Update schema for townhouse walls by @bpark1327 in #175
Duct blaster measurements by @bpark1327 in #168
Update hpxml2hescore duct validation by @bpark1327 in #173
Update duct blaster measurement by @bpark1327 in #183
Low-e storms by @bpark1327 in #176
Increase granularity of construction codes by @bpark1327 in #187
Improve air infiltration measurement translation by @bpark1327 in #190
Fix inappropriate water heater EFs by @bpark1327 in #191
Remove old wall construction codes by @bpark1327 in #195
Improve multiple ducts translation by @bpark1327 in #194
Improve air infiltration measurement translation, Take 2 by @bpark1327 in #193
Updating garage duct location to unvented_crawl by @nmerket in #197
Full Changelog: https://github.com/NREL/hescore-hpxml/compare/v6.2..v7.0